Synea Vision turbines
Discover the Synea Vision turbines for yourself!
-
Click on the Icon to place the Synea Vision Turbine virtually in your practice and see for yourself how well it fits.Drag the mouse in any direction to view the product from all sides.
Open the website with your mobile phone and experience the Synea Vision Turbine in your practice!
The new range of Synea Vision turbine handpieces
Discover the Synea Vision line – the turbine range for all treatment scenarios!
Your advantages at a glance
- 100% shadowless illumination of the treatment site with the Ring LED+ ring (with the RotoQuick system only)
- Optimal Power
- Optimum cooling of the treatment site with 5x Spray
- Four head sizes for every application case
- Hygienic head system
- Scratch-resistant surface improves aesthetics even more – and extends their life
- Fatigue-free work
- Optimum service life and unexpected quietness during operation with ceramic ball bearings
- Thermo washer disinfectable and sterilizable
- 24 months warranty
Power Blade rotorFull steam ahead with the Power Blade rotor
The optimized blade geometry
allows higher rotor efficiency.
For maximum torque and optimal
power throughout preparation.Patented hygienic
head systemPatented hygienic head system
The circulating air in the turbine head ensures no aerosol particles are sucked into the turbine as the rotor slows down.Optimum coolingOptimum cooling
Thanks to the 4x or 5x spray, the bur tip is optimally cooled in every application position.MicroturbineSmall but impressive
LED+ in the microturbine:
small space, plenty of light.
The new TK-94 microturbine for
areas that are difficult to access.Ring LED+Ring LED+
Ring LED+: the only sterilizable 5x Ring LED+ in the world guarantees shadow-free illumination at the treatment site, for the first time ever!Compare illumination
in dental turbines!Light comparison
Hygiene with no compromiseHygiene with no compromise
Minimal escape of air at the head maximum capacity for added efficiency and unbeatable hygiene.
red: popular turbines with high wattage
green: Synea Vision TK-100 L
Synea Vision Turbines
TK-94
LED+,
5x Spray,
Head size Ø 9 mm,
14 W*, 410,000 rpm,
FG burs Ø 1.6 mm for bur lengths up to 16 mm
TK-94 L
REF 30016000LED+, ceramic ball bearings,
coupling system Roto QuickTK-94 LM
REF 30031000Compact glass rod, ceramic ball bearings,
coupling system Multiflex®**TK-100
Ring LED+
5x Spray,
Compact glass rod,
Head size Ø 13 mm,
26 W*, 330,000 rpm,
FG burs Ø 1.6 for bur lengths up to 25 mm
TK-100 L
REF 30021000Ring LED+, ceramic ball bearings,
coupling system Roto QuickTK-100 LM
REF 30022000Compact glass rod, ceramic ball bearings,
coupling system Multiflex®**
TK-98
Ring LED+
5x Spray,
Compact glass rod,
Head size Ø 11,5 mm,
24 W*, 360,000 rpm,
FG burs Ø 1.6 mm for bur lengths up to 25 mm
TK-98 L
REF 30019000Ring LED+, ceramic ball bearings,
coupling system Roto QuickTK-98 LM
REF 30020000Compact glass rod, ceramic ball bearings,
coupling system Multiflex®**TK-97
Ring LED+
5x Spray,
Compact glass rod,
Head size Ø 10 mm,
21 W*, 400,000 rpm,
FG burs Ø 1.6 mm for bur lengths up to 21 mm
TK-97 L
REF 30017000Ring LED+, ceramic ball bearings,
coupling system Roto QuickTK-97 LM
REF 30018000Compact glass rod, ceramic ball bearings,
coupling system Multiflex®*** Performance value applies at a rated pressure of 3 bar and exhaust air pressure of max. 0.2 bar
** Multiflex®is a trademark of a third party not Affiliated with W&H Dentalwerk Bürmoos GmbH.Download Område
FAQ
- Is the new LED turbine from the Synea series e.g. compatible with the existing 924 couplings?
- Which burs can be used with W&H turbines?
- How does the new W&H Click & Pull system work? How do I remove a turbine?
- Why is a 6-hole connection required for the use of an LED turbine?
- What is the maximum length of the rotary instruments?
- I've just bought a new W&H turbine? Should I call a serviceman for my unit to install it?
- At the moment I have a W&H turbine without light. How can I have a light in my turbine?
- My turbine doesn't have enough power/speed?
- Can my W&H turbine be processed via sterilizer?
- Can my W&H turbine be processed via thermal disinfector?
Video lektioner
Brugermanual
Find all languages of the Update Hygiene and Maintenance (EN ISO 17664:2017) in the Download Centre.
Download
-
Outstanding price-performance ratio experience
Uncompromising user comfort with optimal LED-illumination, Quattro Spray and quiet, vibration-free operation.
Your advantages at a glance
- Largest illumination field with LED+
-
Optimum access, best view and high
power with perfect head size
to performance ratio - Safe cooling with Quattro Spray (4 port spray)
- Hygiene head system
-
Ceramic ball bearings for quiet,
vibration-free operation -
Optimised design for secure grip
and optimum hygiene - Secure grip and easy bur changes with the push-button chuck system
- Thermo washer disinfectable sterilizable
- 12 months warranty
Optimum coolingOptimum cooling of four sides
Continuous cooling with Quattro Spray.Best ergonomicsBest ergonomics
Synea turbines are comfortable in the hand and have a non-slip coating.Experience LED+Experience LED+
Optimum illumination, natural colour reproduction and LED positioned directly beneath the instrument head.
Synea Fusion Turbines
TG-97
Quattro Spray
Head size Ø 10 mm,
18 W*, 390,000 rpm,
FG burs Ø 1.6 for bur lengths up to 21 mm
TG-97
REF 30005000Without light, ceramic ball bearings,
coupling system Roto QuickTG-97 L
REF 30004000LED+, ceramic ball bearings,
coupling system Roto QuickTG-97 LM
REF 30006000Compact glass rod, ceramic ball bearings,
coupling system Multiflex®**TG-98
Quattro Spray,
Head size Ø 11,5 mm,
21 W*, 360,000 rpm,
FG burs Ø 1.6 mm for bur lengths up to 25 mm
TG-98
REF 30002000Without light, ceramic ball bearings,
coupling system Roto QuickTG-98 L
REF 30001000LED+, ceramic ball bearings,
coupling system Roto QuickTG-98 LM
REF 30003000Compact glass rod, ceramic ball bearings,
coupling system Multiflex®*** Performance value applies at a rated pressure of 3 bar and exhaust air pressure of max. 0.2 bar
** Multiflex®is a trademark of a third party not Affiliated with W&H Dentalwerk Bürmoos GmbH.Download Område
FAQ
- Is the new LED turbine from the Synea series e.g. compatible with the existing 924 couplings?
- Which burs can be used with W&H turbines?
- How does the new W&H Click & Pull system work? How do I remove a turbine?
- Why is a 6-hole connection required for the use of an LED turbine?
- What is the maximum length of the rotary instruments?
- I've just bought a new W&H turbine? Should I call a serviceman for my unit to install it?
- At the moment I have a W&H turbine without light. How can I have a light in my turbine?
- My turbine doesn't have enough power/speed?
- Can my W&H turbine be processed via sterilizer?
- Can my W&H turbine be processed via thermal disinfector?
Brugermanual
Find all languages of the Update Hygiene and Maintenance (EN ISO 17664:2017) in the Download Centre.
Video lektioner
Download
-
Synea Vision
Types: TK-94 L / TK-94 LM TK-97 L / TK-97 LM TK-98 LM TK-100 LM Light: LED+ /
compact glass rod
Ring LED+ /
compact glass rod
Ring LED+ /
compact glass rod
Ring LED+ /
compact glass rod
Coupling: W&H Roto Quick /
Multiflex®**
W&H Roto Quick /
Multiflex®**
W&H Roto Quick /
Multiflex®**
W&H Roto Quick /
Multiflex®**
Head size: Ø 9 mm Ø 10 mm Ø 11,5 mm Ø 13 mm Head height: 17,2 mm
(with bur 16 mm)21,1
(with bur 19 mm)21,4
(with bur 19 mm)21,4
(with bur 19 mm)Power: 14 W* 21 W* 24 W* 26 W* Speed (± 30.000 rpm): 410.000 rpm 400.000 rpm 360.000 rpm 330.000 rpm FG bur Ø 1.6
Max. operating part diameter:
Max. length:
1,5 mm
16 mm
2 mm
21 mm
2 mm
25 mm
2,5 mm
25 mmOperating pressure Roto Quick-connection:
Operating pressure Multiflex®**-connection:3 ± 0.3 bar
2.5 – 4 bar3 ± 0.3 bar
2.5 – 4 bar3 ± 0.3 bar
2.,5 – 4 bar3 ± 0.3 bar
2.5 – 4 barSpray: 5-fold 5-fold 5-fold 5-fold Synea Fusion
Types: TG-98 L / TG-98 TG-97 L / TG-97 TG-98 LM TG-97 LM Light: LED+ / no LED+ / no compact glass rod compact glass rod Coupling: Roto Quick Roto Quick Multiflex®*
Multiflex®* Head size: Ø 11,5 mm Ø 10 mm Ø 11,5 mm Ø 10,5 mm Head height: 21,4 mm
(with bur 19 mm)21,1 mm
(with bur 19 mm)21,4 mm
(with bur 19 mm)21,1 mm
(with bur 19 mm)Power: 21 W* 18 W* 21 W* 18 W* Speed (± 30.000 rpm): 360.000 rpm 390.000 rpm 360.000 rpm 360.000 rpm FG bur Ø 1.6
Max. operating part diameter:
Max. length:2 mm
25 mm2 mm
21 mm2 mm
25 mm2 mm
21 mmOperating pressure Roto Quick-connection:
Operating pressure Multiflex®**-connection:3 ± 0,3 bar
2,5 – 4 bar3 ± 0,3 bar
2,5 – 4 bar3 ± 0,3 bar
2,5 – 4 bar3 ± 0,3 bar
2,5 – 4 barSpray: 4-fold
4-fold
4-fold 4-fold All types are also available without light.
Power and speed data of air driven motors are largely dependent on the quality of the turbine hoses used
and may therefore differ from the specified values.
* Performance value applies at a rated pressure of 3 bar and exhaust air pressure of max. 0.2 bar
** Multiflex®is a trademark of a third party not Affiliated with W&H Dentalwerk Bürmoos GmbH.